Service Agreement & Warranty Terms

Terms of Service

Professional standards, transparent warranty policies, safety protocols, and consumer protection agreements for residential and commercial electrical repairs in Mianwali, Punjab.

Effective Date: October 2026
Governing Framework: Punjab Consumer Protection Act (PCPA) 2005
Jurisdiction: District Mianwali, Punjab, Pakistan

30-Day Copper Warranty

All motor rewinds use certified 99.9% electrolytic pure copper wire and Class H (180°C) thermal insulation.

Physical Testing Rule

WhatsApp and phone estimates are provisional; binding pricing requires on-site instrument diagnostics.

Safety & Isolation

Customers must ensure clear DB access and disclose active solar inverter or UPS back-feed connections.

Transparent PKR Billing

Agreed quotes before work begins; itemized receipts detailing wire weight, replacement parts, and labor.

1Scope of Services and Agreement Acceptance

These Terms of Service constitute a legally binding agreement between you (the "Client" or "Customer") and Apka Rafique, an electrical contracting and workshop sole proprietorship owned and operated by Lead Electrician Muhammad Rafique, Near Noor Mahal Marquee, Mianwali City, Punjab, Pakistan.

Apka Rafique provides professional doorstep electrical repairs, distribution board (DB) installation and phase load balancing, industrial and agricultural motor rewinding, solar DC and AC breaker integration, tubular battery maintenance, and urgent fault isolation across Mianwali City and surrounding union councils.

Scheduling a service visit, requesting a quote via telephone, initiating diagnostic consultations via WhatsApp (0334 7656994), or submitting a booking request on apkarafique.pk/contact confirms your unconditional agreement to these terms.

2Electrical Diagnostic Disclaimers and Quotations

Electrical systems carry latent hazards and hidden variables that cannot be fully diagnosed through verbal description or mobile screen imagery alone:

  • Preliminary Estimates: Any cost projection provided via phone or WhatsApp before on-site inspection is an approximate estimate based solely on customer description. It does not constitute a final binding contract.
  • Concealed Infrastructure Realities: Alternating current (220V single-phase / 400V three-phase) installations often involve hidden hazards—including subterranean conduit moisture, neutral-earth leakage loops, sub-standard prior splices, or deteriorated insulation behind masonry walls.
  • Mandatory Instrument Verification: A binding quotation is established only after our technician performs hands-on physical testing with calibrated instruments (including digital insulation megohmmeters, true-RMS clamp meters, and earth loop testers).
  • Diagnostic Callout Fee: If a technician visits your premises, performs diagnostic testing, and provides an itemized repair estimate, a standard callout/diagnostic fee is payable if the customer chooses not to proceed with the recommended repair.

3Motor Rewinding Metallurgy and 30-Day Warranty Standards

Apka Rafique upholds uncompromising metallurgical standards in our workshop motor rewinding operations:

100% Pure Copper Guarantee

We wind exclusively with 99.9% electrolytic grade pure copper magnet wire (Pakistan Cables or certified grade). We reject Copper-Clad Aluminum (CCA) wire, which suffers 68% higher electrical resistance and causes rapid thermal burnout in Mianwali's 45°C+ summer heat.

Class H (180°C) Insulation

All stator slots are lined with Class H Nomex/Mylar composite insulation, heavy-build fiberglass sleeving, and baked insulating varnish to prevent dielectric breakdown under severe thermal cycles.

Scope of 30-Day Craftsmanship Warranty

Apka Rafique provides a 30-Day Workshop Craftsmanship Warranty covering internal winding failure, coil insulation breakdown, or craftsmanship defects from the date of handover.

Express Invalidation Conditions (Warranty Exclusions)

In strict compliance with industry engineering standards, the 30-day warranty is immediately voided if failure results from any of the following operational or environmental factors beyond our control:

  • Extreme WAPDA Grid Voltage Swings: Motor operation during severe line voltage drops below 180V AC or surge spikes exceeding 260V AC without a functioning digital phase/voltage protector.
  • Incorrect Running Capacitor Sizing: Installation of oversized capacitors (e.g., fitting 3.5µF or 5.0µF on a standard ceiling fan specified for 2.5µF) to artificially increase RPM, which pushes auxiliary winding current beyond thermal limits.
  • Mechanical Bearing Seizure: Locked rotor conditions resulting from worn, dry, or seized ball bearings (6201, 6202, 6203, 6305), causing high inrush locked-rotor amperage that melts winding enamel.
  • Single-Phasing on 3-Phase Motors: Running three-phase industrial motors when one supply phase drops out, in the absence of a magnetic contactor with phase-failure protection.
  • Water Immersion & Flooding: Moisture ingress, rainwater submergence, sewage backflow, or operating in direct unshielded agricultural irrigation spray.
  • Unauthorized Tampering: Any opening, testing, re-varnishing, or alteration by an uncertified third-party mechanic.

4On-Site Safety Protocols and Customer Responsibilities

Electrical testing and installation work involves life-safety considerations. Customers must comply with the following safety protocols:

  • Unobstructed Workspace: Customers must ensure clear, unobstructed, and illuminated access to the main distribution board (DB), energy meter, and disconnect switches.
  • Mandatory Auxiliary Power Disclosure: Customers MUST declare all auxiliary power sources—including rooftop solar inverters, UPS battery systems, and backup generators—prior to technician inspection. Back-feed currents from automated transfer switches (ATS) or solar inverters pose fatal electrocution risks to technicians working on de-energized circuits.
  • Securing Dependents and Pets: Children and household pets must remain strictly outside the testing zone while live circuit measurements, arc-fault testing, or 500V/1000V megger insulation testing are active.
  • Imminent Hazard Warnings:If our technician identifies critical safety violations (such as lack of earth connection on water geysers, uninsulated live busbars, or bypassed RCCBs), we will issue a verbal and written warning. Operating defective equipment after such notification is at the customer's sole peril.

5Transparent PKR Pricing and Payment Terms

Apka Rafique adheres strictly to transparent, itemized billing practices:

  • Official Currency: All quotations, material invoices, and technician fees are stated and payable in Pakistani Rupees (PKR).
  • Payment Modes: We accept Cash on Delivery, JazzCash, EasyPaisa, or direct online bank transfer (1Link Raast).
  • Payment Schedule: Residential maintenance and on-site repair fees are payable upon job completion. Motor rewinds must be paid in full upon collection or delivery from our Mianwali workshop. For large-scale rewiring or solar panel DC cabling, an advance deposit covering material procurement will be agreed upon before purchasing copper wire and breakers.
  • Itemized Documentation: Every service is accompanied by an itemized breakdown specifying copper weight used, parts replaced, diagnostic findings, and labor charges.

6Limitation of Liability under the Punjab Consumer Protection Act 2005

Apka Rafique honors all statutory obligations under the Punjab Consumer Protection Act (PCPA) 2005 while maintaining commercially reasonable limits of liability:

  • Direct Damage Cap:In the event of proven direct property damage caused solely by gross negligence during authorized repair work, Apka Rafique's financial liability is strictly capped at the total service charge paid for that specific service engagement.
  • Consequential Damages Exclusion: Apka Rafique shall not be held liable for indirect, incidental, or consequential damages—including food spoilage from prolonged refrigerator outages, business interruption, lost solar feed-in tariffs, or WAPDA grid transformer failures.
  • Pre-Existing Sub-Surface Defects: We bear no liability for pre-existing latent defects, including embrittled cables inside walls, non-standard neutral loops created by prior uncertified workers, or masonry damage resulting from clearing blocked conduits.

7Governing Law and District Mianwali Jurisdiction

These Terms of Service are governed by and construed in accordance with the laws of the Islamic Republic of Pakistan and the statutory regulations of the Province of Punjab.

Any dispute, controversy, or claim arising out of or relating to electrical repair services, motor rewinding warranties, or website use that cannot be resolved amicably through good-faith technical consultation shall be submitted to the exclusive jurisdiction of the competent courts or the District Consumer Protection Court of Mianwali, Punjab.

8Contact Information and Workshop Consultations